HandyDust App screenshot LAAPTOF DAQ screenshot Service


Welcome!

Photo: LAAPTOF We at AeroMegt GmbH are the experts in the development of instrumentation to measure aerosol particles. We support you to become familiar with our instruments and provide technical help throughout your projects. Don't miss the advantages of cooperating with our experts.

Our single particle aerosol mass spectrometer, the LAAPTOF (Laser Ablation of Aerosol Particles Time Of Flight Mass Spectrometer) is capable of analyzing aerosol particles in the range of 70 nm to 2500 nm. It provides you with combined information on the size of the particles and their chemical signature. These extraordinary capabilities render the LAAPTOF suitable for a multitude of different applications.

One example are air quality measurements. No matter whether your target particles have been emitted by factories, engines or wild fires, the LAAPTOF is the instrument of choice to provide a detailed analysis of the fine particle fraction of the aerosol. Thus the LAAPTOF provides you with the necessary information to assess the health impact of emitted aerosols and act accordingly to avoid them. Using this information, companies can design their products to comply with future health regulations right from the start, avoiding expensive reworks. In addition, health agencies can design regulations in a way to efficiently target those emissions that are really relevant.

Processes to synthesize aerosol particles often need to produce chemically homogenous particles. Controlling such a process can be easily achieved using the LAAPTOF. In contrast to the analysis of filter samples, the LAAPTOF provides online analysis of individual particles, avoiding sampling and storing artifacts of filter based techniques. The LAAPTOF spectra reveal if your aerosol particles are externally mixed and thus if your process is inhomogeneous.

Scientifically, the LAAPTOF can be applied in several areas of interest. Use the LAAPTOF in your laboratories or in the field to get insight in the properties of your aerosol particles. The LAAPTOF provides you with the combined information on your particles' (vacuum aerodynamic) diameter and their chemical composition. Since the LAAPTOF uses laser ablation to evaporate and ionize the particles, even those particles that are refractory in thermal desorption based instruments are covered. Thus, beside the typical organic and inorganic compounds covered by thermal desorption instruments, the LAAPTOF also covers mineral dust and soot particles. Since the biologic particles can be analyzed too, the LAAPTOF is the ideal instrument for the analysis of ice nuclei and geological emissions.

Products


LAAPTOF

Photo: LAAPTOF The LAAPTOF (brochure) has been developed to chemically and physically analyze single aerosol particles by the means of time of flight mass spectrometry. The instrument is composed of three regions: the inlet system, the particle time of flight (PTOF) region and the ablation/mass spectrometer region. Together, these regions constitute a differentially pumped vacuum system, which pressure decreases towards the mass spectrometer. On the one hand this is important to provide the vacuum needed by the mass spectrometer and on the other hand it separates the particles from their carrying gas, which greatly improves the signal to noise ratio.

The inlet system is composed of a critical orifice followed by an aerodynamic particle lens. The critical orifice reduces the flow to approximately 100 ml/min ensuring optimal pressure and flow conditions to operate the aerodynamic lens. The aerodynamic lens constitutes a series of orifices, which are designed to focus the aerosol particles on a narrow beam, while defocusing the molecules of the carrier gas. The last orifice of the aerodynamic lens is operated with a critical pressure drop. This results in a supersonic expansion of the aerosol, accelerating the particles into the vacuum of the PTOF region and the mass spectrometer. The particles are accelerated to different velocities according to their vacuum aerodynamic diameter.

In the second region, the particle velocity is determined from the time of flight between two light scattering stages. The signal of the second light scattering stage is used to trigger the ablation/ionization laser. After calibration with size standards, the PTOF is converted into diameters.

The third region is the time of flight mass spectrometer (TOF). In this region the particles are evaporated and ionized using LDI (laser desorption ionization) by a pulsed UV laser. The laser pulse causes extreme thermal stress on the particles, which are evaporated and ionized at the same time. The positive as well as the negative ions are analyzed in a bipolar time of flight mass spectrometer. Since the particles do not impact on a surface prior to their analysis, artifacts from particle surface interaction are avoided.

LPL-2.5

Photo: LPL-2.5 The LPL-2.5 is an aerodynamic particle lens with high transmission efficiency for particles in the diameter range of below 100 nm to above 2.5 µm. The lens has been characterized in two independent measurements. For the first measurement the lens was installed in an Aerodyne Research Inc. Q-AMS. The Q-AMS was operated in single particle detection mode sampling size selected particles. The AMS counts were compared to a TSI 3025 CPC. For the second measurement the lens was installed on an Aerodyne Research Inc. TOF-AMS. The mass concentration was compared to the mass concentration calculated from CPC measurements. The graph below shows the measured transmission for this lens in the range of 70 nm to 2000 nm in diameter. The scattering of the data is due to measurement uncertainties. No trend in transmission efficiency can be seen for particles larger than 100 nm.

Graph: LPL-2.5 transmission

HandyDust

Photo: Handy dust The HandyDust monitor immediately displays the particulate matter concentration.

It is as simple as this:
  1. Connect the sensor to your Android device
  2. Press start

Only 100 € including App (shipping fees apply)

To order, please go to our German web page or call +49 (0)212/38298810

Description:

The HandyDust sensor uses an optical method for measurement of particulate matter concentration, which is converted into a mass concentration value using reasonable assumptions. It measures concentrations from a few µg/m³ to 300 µg/m³.

The sensor is connected to the micro USB port of your Android device. If the HandyDust App is installed (available for free from the Google PlayStore), it is automatically started every time the sensor is connected to the device. The current aerosol concentration is shown as well as a diagram with the temporal evolution.

System requirements:

  • Android 6.0 or newer
  • USB OTG support

Dimensions:

  • Case: 50 mm x 49 mm x 22 mm
  • Connector length: 9 mm

Environmental conditions:

  • Operation temperature: -10 to +65 °C
  • Storage temperature: -20 to +80 °C

Lead time: up to 3 weeks (depending on the availability).

LAAPTOF AnalysisPro

The revolutionary LAAPTOF AnalysisPro is changing the data analysis for single particle mass spectrometers. The software includes massive enhanced versions of both the online data acquisition and the offline data analysis software. Some of the new features included in the "Pro" version are:

Data acquisition:

  • Online source apportionement
  • Spectra are processed online for display

Data analysis:

  • Offline source apportionment for known sources
  • Offline analysis for identification of unknown sources
  • Automated calibration routine
  • Time series
  • Size resolved source analysis
  • Optimized utilization of up-to-date processors

For further information please contact info@aeromegt.com .

VAMPS

VAMPS is an aerosol particle counter which provides the aerodynamic diameter of the particles in addition to their number concentration. The instrument is currently under development and targets simple applications. Accordingly, the instrument will be available for a relatively low price. Details will follow.

Service

Aerosol mass spectrometer support

Support for aerosol mass spectrometers We provide technical support for aerosol mass spectrometers. If you want to set up a new instrument, optimize the tuning, or analyze a complex data set - contact us for support!

Consulting in the field of aerosol technology

You need technical assistance or scientific advice? Our experts in the field of aerosol science and technology are ready to help and support you!

Laboratory and field projects

You are planning a measurement campaign and want a detailed characterization of aerosol particles? Our LAAPTOF is what you need!
You can not afford to purchase an instrument on your own? We do contract work too and can run the measurement for you using one of our instruments. If you want we can even analyze the data for you!

Expertise on fine particulate matter

Expertise In addition to classical laboratory and field projects we offer expertise on fine particulate matter. Our services include planning and execution of measurements as well as evaluation of the data with respect to your specific questions and needs.


Our distributor for Japan
Contact: info@shorelinesci.jp

Under construction

About us

The AeroMegt GmbH is a start-up company dedicated to the development of aerosol measurement instrumentation. We are located in Solingen, Germany, close to the cities of Düsseldorf and Cologne. Beside the development of instrumentation, we provide service for aerosol mass spectrometers and consulting in the field of aerosol science and technology.

CEO

  • Stefan Trimborn, Dipl.-Ing., Dipl.-WirtschIng.(FH)
  • Dr. rer. nat. Achim Trimborn (Dipl. Phys.)
    • PhD at the University of Gießen
    • Senior Scientist at Aerodyne Research, Inc.
    • Guest scientist at the Forschungszentrum Jülich

Scientific staff

  • Dr. rer. nat. Sören Zorn (Dipl. Met.)
    • PhD at the University of Mainz / MPI for Chemistry
    • Postdoctoral Researcher at the Harvard University, Cambridge (MA), Environmental Chemistry Department (USA)
  • Dr. rer. nat. Paul Reitz (Dipl. Phys.)
    • PhD at the University of Mainz / MPI for Chemistry
    • Postdoctoral Research Assistant at the Pacific Northwest National Laboratory, Richland (USA)
  • Dr. rer. nat. Moritz Mann (Dipl. Chem.)
    • PhD at the University of Mainz
Aeromegt GmbH
Olof-Palme-Str. 7a
42657 Solingen
Germany

phone +49 (0)212/38298810
fax +49 (0)212/38298812


email: info@aeromegt.com


CEO:
Dipl. Ing. Stefan Trimborn
s.trimborn@aeromegt.com

CTO:
Dr. Achim Trimborn
a.trimborn@aeromegt.com

Impressum

Angaben gemäß § 5 TMG:

aeromegt GmbH
Am Hüpplingsgraben 14
42799 Leichlingen

Vertreten durch:

Stefan Trimborn
Dr. Achim Trimborn

Kontakt:

Telefon:

+49 (0)212/38298810

Telefax:

+49 (0)212/38298812

E-Mail:

a.trimborn@aeromegt.com

Registereintrag:

Eintragung im Handelsregister.
Registergericht:Köln
Registernummer: HRB 68812

Umsatzsteuer-ID:

Umsatzsteuer-Identifikationsnummer gemäß §27 a Umsatzsteuergesetz:
DE270787419

Quelle: eRecht24, Rechtsanwalt für Internetrecht Sören Siebert

Haftungsausschluss:

Haftung für Inhalte

Die Inhalte unserer Seiten wurden mit größter Sorgfalt erstellt. Für die Richtigkeit, Vollständigkeit und Aktualität der Inhalte können wir jedoch keine Gewähr übernehmen. Als Diensteanbieter sind wir gemäß § 7 Abs.1 TMG für eigene Inhalte auf diesen Seiten nach den allgemeinen Gesetzen verantwortlich. Nach §§ 8 bis 10 TMG sind wir als Diensteanbieter jedoch nicht verpflichtet, übermittelte oder gespeicherte fremde Informationen zu überwachen oder nach Umständen zu forschen, die auf eine rechtswidrige Tätigkeit hinweisen. Verpflichtungen zur Entfernung oder Sperrung der Nutzung von Informationen nach den allgemeinen Gesetzen bleiben hiervon unberührt. Eine diesbezügliche Haftung ist jedoch erst ab dem Zeitpunkt der Kenntnis einer konkreten Rechtsverletzung möglich. Bei Bekanntwerden von entsprechenden Rechtsverletzungen werden wir diese Inhalte umgehend entfernen.

Haftung für Links

Unser Angebot enthält Links zu externen Webseiten Dritter, auf deren Inhalte wir keinen Einfluss haben. Deshalb können wir für diese fremden Inhalte auch keine Gewähr übernehmen. Für die Inhalte der verlinkten Seiten ist stets der jeweilige Anbieter oder Betreiber der Seiten verantwortlich. Die verlinkten Seiten wurden zum Zeitpunkt der Verlinkung auf mögliche Rechtsverstöße überprüft. Rechtswidrige Inhalte waren zum Zeitpunkt der Verlinkung nicht erkennbar. Eine permanente inhaltliche Kontrolle der verlinkten Seiten ist jedoch ohne konkrete Anhaltspunkte einer Rechtsverletzung nicht zumutbar. Bei Bekanntwerden von Rechtsverletzungen werden wir derartige Links umgehend entfernen.

Urheberrecht

Die durch die Seitenbetreiber erstellten Inhalte und Werke auf diesen Seiten unterliegen dem deutschen Urheberrecht. Die Vervielfältigung, Bearbeitung, Verbreitung und jede Art der Verwertung außerhalb der Grenzen des Urheberrechtes bedürfen der schriftlichen Zustimmung des jeweiligen Autors bzw. Erstellers. Downloads und Kopien dieser Seite sind nur für den privaten, nicht kommerziellen Gebrauch gestattet. Soweit die Inhalte auf dieser Seite nicht vom Betreiber erstellt wurden, werden die Urheberrechte Dritter beachtet. Insbesondere werden Inhalte Dritter als solche gekennzeichnet. Sollten Sie trotzdem auf eine Urheberrechtsverletzung aufmerksam werden, bitten wir um einen entsprechenden Hinweis. Bei Bekanntwerden von Rechtsverletzungen werden wir derartige Inhalte umgehend entfernen.

Datenschutz

Die Nutzung unserer Webseite ist in der Regel ohne Angabe personenbezogener Daten möglich. Soweit auf unseren Seiten personenbezogene Daten (beispielsweise Name, Anschrift oder eMail-Adressen) erhoben werden, erfolgt dies, soweit möglich, stets auf freiwilliger Basis. Diese Daten werden ohne Ihre ausdrückliche Zustimmung nicht an Dritte weitergegeben.

Wir weisen darauf hin, dass die Datenübertragung im Internet (z.B. bei der Kommunikation per E-Mail) Sicherheitslücken aufweisen kann. Ein lückenloser Schutz der Daten vor dem Zugriff durch Dritte ist nicht möglich.

Der Nutzung von im Rahmen der Impressumspflicht veröffentlichten Kontaktdaten durch Dritte zur Übersendung von nicht ausdrücklich angeforderter Werbung und Informationsmaterialien wird hiermit ausdrücklich widersprochen. Die Betreiber der Seiten behalten sich ausdrücklich rechtliche Schritte im Falle der unverlangten Zusendung von Werbeinformationen, etwa durch Spam-Mails, vor.

Quellverweis: eRecht24 Disclaimer

Datenschutzerklärung

Wir speichern Ihren Namen, Email-Adresse und Ihre Adresse sowie ggf. Ihre Telefonnummer bis zur vollständigen Erfüllung unseres Kaufvertrages, also bis zum Versand Ihrer bestellten Ware. Für andere Zwecke als für die Bestellung verwenden wir Ihre Daten nicht. Wenn der Bestellvorgang abgeschlossen ist, werden Ihre Daten wieder gelöscht.

Widerrufsbelehrung

Widerrufsrecht

Sie haben das Recht, binnen vierzehn Tagen ohne Angabe von Gründen diesen Vertrag zu widerrufen.

Die Widerrufsfrist beträgt vierzehn Tage ab dem Tag an dem Sie oder ein von Ihnen benannter Dritter, der nicht der Beförderer ist, die Waren in Besitz genommen haben bzw. hat.

Um Ihr Widerrufsrecht auszuüben, müssen Sie uns (AeroMegt GmbH, Olof-Palme-Str. 7a, 42657, Solingen, Telefon +49 (0)212/38298810, Fax +49 (0)212/38298812, E-Mail: info@aeromegt.com) mittels einer eindeutigen Erklärung (z.B. ein mit der Post versandter Brief, Telefax oder E-Mail) über Ihren Entschluss, diesen Vertrag zu widerrufen, informieren. Sie können dafür das beigefügte Muster Widerrufsformular verwenden, das jedoch nicht vorgeschrieben ist.

Zur Wahrung der Widerrufsfrist reicht es aus, dass Sie die Mitteilung über die Ausübung des Widerrufsrechts vor Ablauf der Widerrufsfrist absenden.

Folgen des Widerrufs

Wenn Sie diesen Vertrag widerrufen, haben wir Ihnen alle Zahlungen die wir von Ihnen erhalten haben, einschließlich der Lieferkosten (mit Ausnahme der zusätzlichen Kosten, die sich daraus ergeben, dass Sie eine andere Art der Lieferung als die von uns angebotene, günstigste Standardlieferung gewählt haben), unverzüglich und spätestens binnen vierzehn Tagen ab dem Tag zurückzuzahlen, an dem die Mitteilung über Ihren Widerruf dieses Vertrags bei uns eingegangen ist. Für diese Rückzahlung verwenden wir dasselbe Zahlungsmittel, das Sie bei der ursprünglichen Transaktion eingesetzt haben. Es sei denn, mit Ihnen wurde ausdrücklich etwas anderes vereinbart; in keinem Fall werden Ihnen wegen dieser Rückzahlung Entgelte berechnet. Wir können die Rückzahlung verweigern, bis wir die Waren wieder zurück erhalten haben oder bis Sie den Nachweis erbracht haben, dass Sie die Waren zurückgesandt haben, je nachdem, welches der frühere Zeitpunkt ist.

Sie haben die Waren unverzüglich und in jedem Fall spätestens binnen vierzehn Tagen ab dem Tag, an dem Sie uns über den Widerruf dieses Vertrags unterrichten an uns zurück zu senden oder zu übergeben. Die Frist ist gewahrt, wenn Sie die Waren vor Ablauf der Frist von vierzehn Tagen absenden.

Sie tragen die unmittelbaren Kosten der Rücksendung der Waren.

Sie müssen für einen etwaigen Wertverlust der Waren nur aufkommen, wenn dieser Wertverlust auf einen zur Prüfung der Beschaffenheit, Eigenschaften und Funktionsweise der Waren nicht notwendigen Umgang mit ihnen zurückzuführen ist.

Muster-Widerrufsformular

Wenn Sie den Vertrag widerrufen wollen, dann füllen Sie bitte dieses Formular aus und senden Sie es zurück.

An

AeroMegt GmbH
Olof-Palme-Str. 7a
42657 Solingen
E-Mail: info@aeromegt.com
Fax: +49 (0)212/38298812

Hiermit widerrufe(n) ich/wir den von mir/uns abgeschlossenen Vertrag über den Kauf der folgenden Waren / die Erbringung der folgenden Dienstleistung:

..............................................................................
..............................................................................

(Name der Ware, ggf. Bestellnummer und Preis) Ware bestellt am:

.............................

Datum
Ware erhalten am:

.............................

Datum
Name und Anschrift des Verbrauchers
...................................
...................................
...................................
...................................

Datum
....................................................
Unterschrift Kunde
(nur bei schriftlichem Widerruf)